Section 4 General Programming
4.3
4.2.4 Changing Operational Modes
If memory is allocated from the USER heap for
LOG
and
MACRO
buffers in the Controller or Peripheral modes, and the operational mode is
changed to one of the Pass-Thru modes, this memory remains allocated and
is not available to the Pass-Thru mode. Pass-Thru modes will function as
described but will not have the full memory available to them. Upon
returning to the Controller or Peripheral mode, the
LOG
and
MACRO
buffers
will be un-modified.
4.3 Clock and Timer Functions
The Micro488/EX has a built in time of day, day of week and date clock. Most
timer features, with the exception of
TIME
OUT
and
DELAY
, are directly a function of
this hardware.
TIME
OUT
and
DELAY
are functions of the Micro488/EX's firmware
operating system. As a result, some time skew may be observed between these
commands with respect to the clock.
Both 12 and 24 hour time output formats are available from the clock. The
relationship between the 12 and 24 hour operations are…
24 Hour 12 Hour
Midnight 00:00:00 12:00:00 AM
01:00:00 01:00:00 AM
……
11:59:59 11:59:59 AM
Noon (Midday) 12:00:00 12:00:00 PM
13:00:00 01:00:00 PM
……
23:59:59 11:59:59 PM
4.3.1 Time
While running one of the TERMINAL programs in Appendix D, type
the following on the PC's keyboard…
HELLO
<return>