Strona 1 -

USER’S MANUAL eZ-Balance Balancing Software for Rotating Machinery eZ-Balance 1086-0925 rev 9.0 IOtech 2597

Strona 2

2-4 A Balancing Project 987091 eZ-Balance After you complete the form and click <OK>, the eZ-Balance Main window will open. The main

Strona 3 - Table of Contents

eZ-Balance 987091 A Balancing Project 2-5 3. Modify the Device Setup for On-line Balancing After you create a new eZ-Balance job, you need to

Strona 4 - 987091 eZ-Balance

2-6 A Balancing Project 987091 eZ-Balance Input Channels Tab Use this panel to configure each channel for your balance job. Select a chann

Strona 5 - What is eZ-Balance?

eZ-Balance 987091 A Balancing Project 2-7 Operation: Initial Balance Run The first step is to perform an initial balance run. This is the “as

Strona 6 - 978691 eZ-Balance

2-8 A Balancing Project 987091 eZ-Balance Click on “Trial Weight 1.” This will automatically save the Initial Run data and Pause the acqu

Strona 7 - Overview of the Balance Job

eZ-Balance 987091 A Balancing Project 2-9 Balance Weights Window Operation: Trial Balance Run Use the same vibration acquisition meth

Strona 8

2-10 A Balancing Project 987091 eZ-Balance Operation: Calculate the Trial Solution Calculate Trial Solution Click the Trial Solution cel

Strona 9 - A Balancing Project 2

eZ-Balance 987091 A Balancing Project 2-11 Operation: Trim Balance Run Trim Balance Run Perform a Trim Balance Run to verify the Balance solu

Strona 10 - 987091 eZ-Balance

2-12 A Balancing Project 987091 eZ-Balance Notes:

Strona 11

eZ-Balance 969391 Windows, Buttons, and Menus 3-1 Windows, Buttons, and Menus 3 The Main Window …… 3-1 Window Selection Buttons …… 3-2 C

Strona 13 - On-line Method

3-2 Windows, Buttons, and Menus 969391 eZ-Balance Windows Selection Buttons The buttons can be used instead of the associated selection in t

Strona 14

eZ-Balance 969391 Windows, Buttons, and Menus 3-3 Control Buttons and Operation Selection Cells The Control section of the main window incl

Strona 15

3-4 Windows, Buttons, and Menus 969391 eZ-Balance Display Task Bar Plot Display Task Bar The Plot Display task bar is located at the top edge

Strona 16

eZ-Balance 969391 Windows, Buttons, and Menus 3-5 Balance Weights Window Balance Weights Window This window contains a table for displa

Strona 17 - Operation: Trim Balance Run

3-6 Windows, Buttons, and Menus 969391 eZ-Balance File Menu The file pull-down menu contains five standard application commands. New eZ-Bal

Strona 18

eZ-Balance 969391 Windows, Buttons, and Menus 3-7 Configuration Menu . . . Analyzer Tab Panel Function(s) Hardware This panel consists of a

Strona 19 - The Main Window

3-8 Windows, Buttons, and Menus 969391 eZ-Balance Edit Menu > Configuration Window > Input Channels Tab The Balance Configuration windo

Strona 20 - Windows Selection Buttons

eZ-Balance 969391 Windows, Buttons, and Menus 3-9 Configuration Window . . . Input Channels Tab Attribute Comments Integration None Sing

Strona 21

3-10 Windows, Buttons, and Menus 969391 eZ-Balance Configuration Window . . . Input Channels Tab Attribute Comments Coupling AC or DC couplin

Strona 22 - Vibration Data Display

eZ-Balance 969391 Windows, Buttons, and Menus 3-11 For Tach Probes, you will need to enter the following information. The tachometer rela

Strona 23 - Balance Weights Window

ZonicBook 987091 eZ-Balance, pg. iii Table of Contents 1 – Installing and Running the Application What is eZ-Balance …… 1-1 Installing and Starti

Strona 24 - Edit Menu

3-12 Windows, Buttons, and Menus 969391 eZ-Balance Edit Menu > Display Preferences From the Display Preferences window you can set plot re

Strona 25

eZ-Balance 969391 Windows, Buttons, and Menus 3-13 Report Menu This menu allows you to generate a report in regard to Balance Solution [if

Strona 26 - Input Channels Tab

3-14 Windows, Buttons, and Menus 969391 eZ-Balance Window Menu The Windows pull-down menu is directly related to the Windows panel. Window Me

Strona 27 - Piezoelectric)

eZ-Balance 939093 Balance Toolkit 4-1 Balance Toolkit 4 Trial Weight …… 4-1 Split Weights …… 4-2 Resolving Weights …… 4-3 Chord-Angle-Arc ……

Strona 28 - 969391 eZ-Balance

4-2 Balance Toolkit 939093 eZ-Balance Split Weights Split Weights Tab – Spread Angle Selected Find Split Weights. There are times when additio

Strona 29

eZ-Balance 939093 Balance Toolkit 4-3 Resolving Weights Resolving Weights Tab This tab is used to calculate the effect of placing multiple

Strona 30 - Operations Menu

4-4 Balance Toolkit 939093 eZ-Balance Runout Compensation Runout Compensation Tab The Runout Compensation Tab is used to find compensated amp

Strona 31 - Report Menu

eZ-Balance 939093 Balance Toolkit 4-5 Unbalance Tolerance Unbalance Tolerance Tab This tab is used to calculate the acceptable amount [the

Strona 32 - Window Menu

4-6 Balance Toolkit 939093 eZ-Balance Stock Weights Stock Weights Tab This tab is used to calculate stock weight, or the length of stock, dep

Strona 33 - Balance Toolkit 4

eZ-Balance 939093 Balance Toolkit 4-7 Drill Bit Weights Drill Bit Weights Tab This tab is used to calculate the drilling depth needed to r

Strona 34 - 939093 eZ-Balance

987091 eZ-Balance This page is intentionally blank.

Strona 35 - Chord-Angle-Arc

4-8 Balance Toolkit 939093 eZ-Balance Arc Weight Arc Weight Tab This tab can be used to calculate the effect of weight added over an arc. It c

Strona 36

eZ-Balance 978691 Installing and Running the Application 1-1 Installing and Running the Application 1 What is eZ-Balance? …… 1-1 Installing

Strona 37 - Unbalance Tolerance

1-2 Installing and Running the Application 978691 eZ-Balance Software Installation 1. Start Windows. 2. Close all running applicat

Strona 38

eZ-Balance 978691 Installing and Running the Application 1-3 Overview of the Balance Job Each balance “job” in eZ-Balance is unique. For exam

Strona 39 - Drill Bit Weights

1-4 Installing and Running the Application 978691 eZ-Balance Connecting the Data Acquisition Device Refer to your hardware documen

Strona 40

eZ-Balance 987091 A Balancing Project 2-1 A Balancing Project 2 1. Start eZ-Balance …… 2-1 2. Create a New Job …… 2-4 3. Modify the Device

Komentarze do niniejszej Instrukcji