Section 4 Serial Controller
4.64
REMOTE
The
REMOTE
command asserts the Remote Enable (REN) bus management line.
If optional bus addresses are specified, then
REMOTE
addresses those devices to listen,
placing them in the Remote Addressed state.
This command does not have a query option.
TYPE High Level Controller command
SYNTAX
REMOTE [addr[,addr
...
]]
addr
is an IEEE 488 bus device address
RESPONSE None
MODE High Level Controller
BUS STATES REN (without addresses)
REN, ATNUNL, MTA, LAG (with addresses)
QUERY None
RESPONSE
EXAMPLES
PRINT #1,"REMOTE"
Assert Remote Enable
PRINT #1,"REMOTE16,28"
Assert Remote Enable and
address devices 16 and 28 to
listen.