Section 4 Serial Controller
4.17
ABORT
The
ABORT
command causes the Interface Clear (IFC) bus management line to
be asserted for at least 500 microseconds. By asserting IFC, the Analyzer488
regains
control of the bus even if one of the devices has locked it up during a data transfer.
ABORT
forces all IEEE 488 bus device interfaces into a quiescent idle state.
This command does not have a query option.
TYPE High Level Controller command
SYNTAX ABORT
RESPONSE None
MODE High Level Controller
BUS STATES IFC, *IFC
QUERY None
RESPONSE
EXAMPLES
PRINT#1,"ABORT"
pulse IFC line