Systems with varying ground potentials should always be monitored in the differential mode. Care is required to assure that the sum
of the input signal and the ground differential (referred to as the common mode voltage) does not exceed the common mode range
of the A/D board (+/-10V on the CIO-DAS6402). Figure 4-6 below show recommended connections in this configuration.
Figure 4-6. Common Mode Voltage < +/-10V / Differential Inputs
4.2.5 COMMON MODE VOLTAGE > +/-10V
The CIO-DAS6402 will not directly monitor signals with common mode voltages greater than +/-10V. You will either need to alter
the system ground configuration to reduce the overall common mode voltage, or add isolated signal conditioning between the
source and your board. See Figure 4-7 and 4-8 below.
Figure 4-7. Common Mode Voltage > +/-10V. Single-Ended Input
Figure 4-8. Common Mode Voltage > +/-10V. Differential Input
4.2.6 ISOLATED GROUNDS / SINGLE-ENDED INPUTS
Single-ended inputs can be used to monitor isolated inputs, though the use of the differential mode will increase you systems noise
immunity. Figure 4-9 below shows the recommended connections is this configuration.
12
+
-
Input
Amp
To A/D
A/D Board
I/O
Connector
LL GND
CH High
CH Low
Signal Source
with Common
M ode Voltage
Signal source and A/D board
with common mode voltage
connected to a differential input.
GND
The voltage differential
between these grounds,
added to the maximum
input signal must stay
within +/-10V
System with a Large Common Mode Voltage,
Connected to a Single-Ended Input
I/O
Connector
+
-
Input
Amp
To A/D
LL GND
CH IN
A/D Board
L
arge common
mode voltage
between signal
source & A/D board
GND
Isolation
Barrier
When the voltage difference
between signal source and
A/D board ground is large
enough so the A/D boards
common mode range is
exceeded, isolated signal
conditioning must be added.
System with a Large Common Mode Voltage,
Connected to a Differential Input
L
arge common
mode voltage
between signal
source & A/D board
GND
Isolation
Barrier
When the voltage difference
between signal source and
A/D board ground is large
enough so the A/D boards
common mode range is
exceeded, isolated signal
conditioning must be added.
+
-
Input
Amp
To A/D
A/D Board
I/O
Connector
LL GND
CH High
CH Low
10 K
10K is a recommended value. You may short LL GND to CH Low
instead, but this will reduce your systems noise immunity.