Measurement-computing CB-7000 DIO Instrukcja Użytkownika Strona 48

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 68
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 47
48
CB-7000 DIO Manual
2.18 ~AA0
Description: Read Module Status
Command: ~AA0[CHK](cr)
~ Delimiter character
AA Address of reading module (00 to FF)
0 Command for read module status
Response: Valid Command: !AASS[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax or communication error may get no response.
! Delimiter for valid Command
? Delimiter for invalid Command
AA Address of response module(00 to FF)
SS Module status, 00=host watchdog timeout status is clear,
04=host watchdog timeout status is set. The status will store
into EEPROM and only may reset by the Command ~AA1.
Example:
Refer to Sec. 2.21, ~AA3EVV example.
Related Command:
Sec. 2.17, ~**; Sec. 2.19, ~AA1; Sec. 2.20, ~AA2; Sec. 2.21,
~AA3EVV; Sec. 2.22, ~AA4V; Sec. 2.23, ~AA5V
Related Topic:
Sec. 3.2, Module Status; Sec. 3.3, Dual Watchdog Operation
Przeglądanie stron 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 67 68

Komentarze do niniejszej Instrukcji

Brak uwag