The data in the counter read register, and the action taken on the data in the counter
load register, is wholly dependent upon control code written to the control register.
The counters are 16 bits, each with an 8-bit window, the read/load register. Data are
shifted into and out of the 16-bit counters through these 8-bit windows according to
the control byte.
5.2.5 Counter Control Register
Base Address + 7
LSBMSB
BCDM0M1M2RL0RL1SC0SC1
01234567
SC1 and SC0 are the counter select bits. The are binary coded between 0 and 2.
SC1 SC2 Counter
0 0 0
0 1 1
1 0 2
RL1 and RL0 are the read and load control bits:
Read/load low then high byte (word transfer).11
Read/load low byte.01
Read/load high byte.10
Latch counter.00
OperationRL0RL1
M2 to M0 are the counter mode control bits:
Counter 0 and Counter 1 are hardware-fixed to operate in Rate Generator mode only.
Rate Generator.010
Operation TypeM0M1M2
Counter 2 can support the following two modes:
Rate Generator.010
Change on terminal count.000
Operation TypeM0M1M2
BCD = 0: The counters are hardware fixed to support 16-bit binary mode only.
16