2.3 OUTPUT RANGE SELECTION
The analog output full-scale ranges are set by DIP switches. Each analog channel has a separate set of switches. The location of the
switches and the channels they control are shown in the Figures 2-2.
CIO-DAC04/12-HS
Figure 2-2. CIO-DAC04/12-HS Switch Locations
Table 2-1 CIO-DAC04/12-HS Range Switch Settings
OFFONOFFOFF0 to 2.5V
ONOFFOFFOFF0 to 5V
OFFOFFOFFOFF0 to 10V
OFFONONON+/-2.5V
ONOFFONON+/-5V
OFFOFFONON+/-10V
S4S3S2S1OUTPUT FULL - SCALE RANGE
NOTE: UP = ON, DOWN = OFF