CB-7021, CB-7022, CB-7024 Users Manual
2.14 $AA8
Description: Current Readback
Note: The command is for CB-7021/21P only.
Syntax: $AA6[CHK](cr)
$ Delimiter character
AA Address of reading module (00 to FF)
8 Command for current readback
Response: Valid Command: !AA(Data)[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
! Delimiter for valid command
? Delimiter for invalid command
AA Address of response module (00 to FF)
(Data) The current output value. Refer to Sec. 1.9 for format.
Example:
Command: $012 Receive: !01320614
Read address 01 configuration, returns output type 0 to 10V,
9600 bps, eng. unit format and slew rate is 1.0V/Second.
Command: #0110.000 Receive: !01
Set address 01 output 10.0V, returns successful.
Command: $016 Receive: !0110.000
Read address 01 last output command value, returns 10.000.
Command: $018 Receive: !0101.000
Read address 01 current value, returns 1.0V.
Command: $018 Receive: !0101.500