USB-PDISO8 User's Guide Installing the USB-PDISO8
Additional documentation
In addition to this hardware user's guide, you should also receive the Quick Start Guide (available in PDF at
www.mccdaq.com/PDFmanuals/DAQ-Software-Quick-Start.pdf
). This booklet supplies a brief description of
the software you received with your USB-PDISO8 and information regarding installation of that software.
Please read this booklet completely before installing any software or hardware.
Unpacking the USB-PDISO8
As with any electronic device, you should take care while handling to avoid damage from static
electricity. Before removing the USB-PDISO8/40 from its packaging, ground yourself using a wrist strap or by
simply touching the computer chassis or other grounded object to eliminate any stored static charge.
If any components are missing or damaged, notify Measurement Computing Corporation immediately by
phone, fax, or e-mail:
Phone: 508-946-5100 and follow the instructions for reaching Tech Support.
Fax: 508-946-9500 to the attention of Tech Support
Installing the software
Refer to the Quick Start Guide for instructions on installing the software on the Measurement Computing Data
Acquisition Software CD. This booklet is available in PDF at www.mccdaq.com/PDFmanuals/DAQ-Software-
Quick-Start.pdf.
Installing the USB-PDISO8
Before you connect the USB-PDISO8 to your computer, connect the external power supply that was shipped
with the device.
You can connect up to four compatible Measurement Computing USB products in a daisy chain configuration
to a single USB 1.1 port or USB 2.0 port on your computer.
Connecting the external power supply
Power to the USB-PDISO8 is provided with the +9 V external power supply (CB-PWR-9). You must connect
the external power supply before connecting the USB cable to the USB-PDISO8 and your computer.
If you are connecting more than one Measurement Computing USB product, make sure that you provide
adequate power to each device. Refer to the "Power limitations using multiple USB-PDISO8 devices" section
on page 3-7.
To connect the power supply to your USB-PDISO8, connect the external power cord to the power connector
labeled
POWER IN on the USB-PDISO8 enclosure (PWR IN on the board). Refer to on page 3-1 for
the location of this connector.
Figure 3-1
The
PWR LED illuminates green when +9 V power is supplied to the USB-PDISO8. If the voltage supply is
less than +6.5 V or more than +12.5 V, the
PWR LED does not light.
Do not connect external power to the POWER OUT connector
The power connector labeled POWER OUT on the enclosure (PWR OUT on the board) is used to provide power
to an additional Measurement Computing USB product. If you connect the external power supply to the
POWER OUT connector, the USB-PDISO8 does not receive power, and the PWR LED does not illuminate.