2.10
2.3.6 Serial Handshake Selection
Switch
SW1-5 is used to select between hardware [
RTS/CTS
] or
software [
Xon/Xoff
] serial handshake control.
With
Xon/Xoff
, the
Serial488A
issues an
Xoff
character [ASCII value
of $13] when its buffer memory is near full. When issued, there is greater
than 1000 character locations remaining to protect against buffer overrun.
When it is able to accept more information it issues an
Xon
character
[ASCII value of $11]. The
Serial488A
also accepts
Xon/Xoff
on transmit
from the serial host it is communicating with.
RTS/CTS
serial control
becomes inactive when
Xon/Xoff
is enabled. The
RTS
output is, however,
set to an active high state. The
CTS
input is not used for this handshake
and may be left floating (unconnected).
With
RTS/CTS
, the
Serial488A
un-asserts
RTS
(low) when its buffer
memory is near full. When un-asserted, there is greater than 1000 character
locations remaining to protect against buffer overrun. When it is able to
accept more information it asserts (high)
RTS
. The
Serial488A
will not
transmit data to the serial host if it detects the
CTS
input un-asserted (low)
when configured for this hardware handshake.
The factory default serial control is hardware,
RTS/CTS
.
SW1 View for Serial Handshake Selection
OPEN
12345678
DOT
Switch
Side
View
OPEN
12345678
RTS/CTS Xon/Xoff