Section 3 Command Descriptions
3.10
Status EOI Kn
The
EOI
line is one of five interface management lines of the IEEE 488 bus. It is
used to indicate the end of a multiple byte message. The Status EOI
command
specifies how this line w ill be used w hen the Serial488/4 sends port and command
status messages to the addressed listener, usually the bus controller. In the
K0
mode,
the
EOI
line is asserted by the Serial488/4 on the last byte of every status message.
In the
K1
mode the
EOI
line is not used. The factory default setting as set by the
Save Configuration command (
S0
) is
K1
,
EOI
is disabled.
K0
Assert EOI on last byte of status message.
K1
EOI is disabled.
K?
Return last EOI command received.
Example 1: Select
EOI
on last byte of message using dual primary addressing mode.
PRINT#1,"OUTPUT08;k0X"
Example 2: Disable
EOI
on status messages using secondary addressing mode.
PRINT#1,"OUTPUT0800;K1X"