Personal488 for Windows 95/98/Me/NT/2000
04-10-01
API Reference 6-48
Reset
Syntax
INT WINAPI Reset(DevHandleT devHandle);
devHandle
refers to either an interface or an external device. If
devHandle
refers to an
external device, the
Reset
command acts on the hardware interface to which the
external device is attached.
Returns
-1
if error
Bus States
None
Example
errorcode=Reset(ieee);
See Also
Abort, Term, TimeOut
The
Reset
command provides a warm start of the interface. Using Reset is equivalent to issuing the
following command process, including clearing all error conditions.
Disarm
Reset hardware (resets to Peripheral if not System Controller)
Abort (if System Controller)
Error ON
Local
Request 0 (if Peripheral)
Clear Change, Trigger, and Clear status
Reset I/O adapter settings to installed values (BusAddress, TimeOut, IntLevel and DmaChannel)