PCIM-DAS16JR/16 User's Guide Specifications
Settling time
Settling time is defined here as the time required for a channel to settle to within a specified accuracy in
response to a full-scale (FS) step. Two channels are scanned at a specified rate with a –FS DC signal presented
to channel 1 and a +FS DC signal presented to channel 0.
Accuracy Condition Range
±0.00076%
(±4 LSB)
±0.0015%
(±8 LSB)
±0.0061%
(±16 LSB)
±10 V Typ. 400 µS 100 µS 10 µS
±5 V Typ. 100 µS 20 µS 10 µS
±2.5 V Typ. 60 µS 12 µS 10 µS
±1.25 V Typ. 50 µS 10 µS
0 to 10 V Typ. 400 µS 100 µS 10 µS
0 to 5 V Typ. 100 µS 20 µS 10 µS
0 to 2 V Typ. 60 µS 12 µS 10 µS
Same range to
same range
0 to 1.25 V Typ. 50 µS 10 µS
Digital input / output
Main connector
Digital output type 5V/TTL compatible
Digital input type 5V/TTL compatible, pulled to logic high via 10 K resistor network
Number of I/O 8
Configuration 4 fixed input, 4 fixed output
Output high voltage 3.8 volts min. @ -32 mA
Output low voltage 0.55 volts max. @ 32 mA
Input high voltage 2.0 volts min., 7 volts absolute max.
Input low voltage 0.8 volts max., -0.5 volts absolute min.
Data transfer Programmed I/O
Power-up / reset state DIG OUT [3:0] - TTL logic low state
6-3