eZ-TOMAS & eZ-TOMAS Remote 887491 Display Menu … Plots Plot Examples 7-5
Time Waveform Compensation (selectable option)
As an option, you can display compensated Time Waveforms. Typically this compensation function is used to remove
shaft runout from the data display.
To use this feature:
(a) view the history data
(b) select the slow roll condition
(c) select: File
(d) select: Export
(e) select: Runout
You can now view data at steady state and select Runout Compensation.
The following example, using channel 14, shows Uncompensated and Compensated plots.