DAQFlex Software User's Guide DAQFlex Message Reference Programming messages AOTRIG
60
AOTRIG
Sets and gets analog output trigger property values.
Refer to the device-specific information in the Hardware Reference section for the component properties
and commands supported by each DAQ device.
Properties
TYPE
TYPE
Set the trigger edge.
Message
"AOTRIG:TYPE=value"
Response
"AOTRIG:TYPE"
value
EDGE/RISING, EDGE/FALLING
Example
"AOTRIG:TYPE=EDGE/RISING"
Get the trigger edge.
Message
"?AOTRIG:TYPE"
Response
"AOTRIG:TYPE=value"
value
EDGE/RISING, EDGE/FALLING
CTR
Sets and gets property values for counter channels.
Refer to the device-specific information in the Hardware Reference section for the component properties
and commands supported by each DAQ device.
Properties
START, STOP, VALUE
(Component only)
Get the number of counter channels on a device.
Message
"?CTR"
Response
"CTR=value"
value
The number of counter channels on a device.
START
Start a specified counter channel.
Message
"CTR{ch}:START"
Response
"CTR{ch}:START"
ch
The number of the counter channel.
Example
"CTR{0}:START"