Measurement-computing PCM-DAS16x/16 Instrukcja Użytkownika Strona 20

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 40
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 19
6.1.2 Single-Ended Inputs
A single-ended input measures the voltage between the input signal and ground. In
this case, in single-ended mode the PCM-DAS16x/16 measures the voltage between
the input channel and LLGND. The single-ended input configuration requires only
one physical connection (wire) per channel and allows the PCM-DAS16x/16 to moni-
tor more channels than the (2-wire) differential configuration using the same connec-
tor and onboard multiplexor. However, since the PCM-DAS16x/16 is measuring the
input voltage relative to its own low level ground, single-ended inputs are more sus-
ceptible to both EMI (Electro Magnetic Interference) and any ground noise at the sig-
nal source. The following diagrams show the single-ended input configuration.
16
Przeglądanie stron 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 39 40

Komentarze do niniejszej Instrukcji

Brak uwag