INTE = 1 enables interrupts (positive edge triggered) onto the PC bus IRQ selected
via the IRQ jumper on the PC104-DAS08.
INTE = 0 disables the passing of the interrupt detected at pin 10 to the PC bus.
IRQ is set to 1 every time an interrupt occurs. If you want to process successive
interrupts then set INTE = 1 as the last step in your interrupt service
routine.
MUX2 to MUX0. Set the current channel address by writing a binary coded number
between 0 and 7 to these three bits.
NOTE
Every write to this register sets the current A/D channel MUX
setting to the number in bits 2-0.
3.4 UNUSED ADDRESS
BASE ADDRESS + 3
This address is not used
3.5 COUNTER LOAD & READ REGISTERS
COUNTER 0
BASE ADDRESS + 4
D0D1D2D3D4D5D6D7
01234567
COUNTER 1
BASE ADDRESS + 5
D0D1D2D3D4D5D6D7
01234567
COUNTER 2
BASE ADDRESS + 6
D0D1D2D3D4D5D6D7
01234567