© National Instruments Ireland Resources Limited | 1-9
Figure 1-6. Displaying Numeric Data in the Digital Meter
7. Stop the measurement after some time.
Saving Measurement Data
Complete the following steps to save the measurement data in a file.
1. Click the Plus sign next to the module group Files in the browser.
a. Select the Write Data module and drag and drop the module into
the worksheet.
b. Double-click the Write Data module to open the dialog box.
c. Click the Plus button next to the channel bar twice, to create two
additional inputs.
d. Click File and enter
MyData.ddf as the file name.
e. Click Save to close the file dialog box.
f. Click OK. DASYLab creates three inputs in the Write Data
module.