3.2.1 ON & OFF for FORM C RELAYS
On means that FORM C relay common is in contact with the Normally-Open
(NO) contact.
Off means that FORM C relay common is in contact with the
Normally-Closed (NC) contact.
3.2.2 ON & OFF FOR FORM A RELAYS
On means that FORM A relay common is in contact with the Normally-Open
(NO) contact.
Off means that FORM A relay common is open.
3.3 INPUT REGISTER
The isolated input register is located at
BASE
address + 1.
WRITE = NO FUNCTION
READ = STATUS: Read the status of the isolated inputs. A one in the input bit
position indicates that a voltage is present at the input.
INPUT #
7 6 5 4 3 2 1 0
BIT No. 76543210
HEX 804020108421
DECIMAL 1286432168421