Chapter 2 Device Function Library
ADAC LabVIEW VI
1
75
Device Handle out Device Handle out contains the value of Device Handle in.
Cycle Mode Cycle Mode is a numeric value that represents the software cycle operation
mode currently configured in the device.
error out Error out contains error information. If the error in cluster indicated an error,
the error out cluster contains the same information. Otherwise, error out describes the
error status of this VI.
ADAC Get DTM (Data Transfer Method)
This VI gets the Data Transfer Method of the device. See the
AL_SetDataTransfeMethod.VI for the available options.
Device Handle (0) Device Handle is a numeric value that is used to identify the device
subsystem. The default Device Handle is 0.
error in (no error) Error in describes error conditions occurring before this VI executes.
This cluster defaults to no error.
Device Handle out Device Handle out contains the value of Device Handle in.
Data Transfer Method Data Transfer Method is a numeric value that represents the
hardware transfer method currently configured in the device.
error out Error out contains error information. If the error in cluster indicated an error,
the error out cluster contains the same information. Otherwise, error out describes the
error status of this VI.